サービス時間: 月曜日~金曜日 9:00-18:00
CJ1W-F159 - CJ1W-F159 AA014406G 192141 OMRON Weighing Module
在庫あり 注目商品

CJ1W-F159

CJ1W-F159 AA014406G 192141 OMRON Weighing Module

$1,860.26米ドル
43 在庫あり
サプライヤー情報
OMRON
OMRON
製品: 41472
通常、2〜3営業日以内に出荷します
品質保証済み
高速配送
テクニカルサポート

製品説明

More details
主な機能
  • 産業グレードの品質
  • RoHS準拠
  • CE認証取得
  • 1年保証

技術的詳細

CJ-Series analogI/O and controlunitsModular PLCFrom basic analog I/O to advanced temperature controlThe CJ-series offers a wide choice of analog input units, fit for any application, from low-speed, multi-channel temperature measurement to high-speed, high-accuracy data acquisition. Analog outputscan be used for accurate control or external indica- tion.Advanced units with built-in scaling, filtering and alarm functions reduce the need for complex PLC programming.High-accuracy process I/O units supportan extensiverange of sensors, for fast and accurate data acquisition. Temperature control units re- lieve the PLC CPU of PID calculations and alarm monitoring. These functions are han- dled autonomously by the unit, offering control performance and auto-tuningfunctions similar to stand-alone temperaturecontrollers.Ordering informationPointsType RangesResolution Accuracy*1Conversion timeWidth RemarksConnection typeOrder code4Universal analog0 to 5VV / I: 1/12,000 V: 0.3%250 ms/4 point 31 mmUniversal inputs, with zero/span adjust-M3 CJ1W-AD04Uinput1 to 5V0 to 10V0 to 20 mA4 to 20 mAK, J, T, L, R, S, B Pt100, Pt1000, JPt100T/C: 0.1°C RTD: 0.1°CI: 0.3% T/C: 0.3%RTD: 0.3%ment, configurable alarms, scaling, sensorScrewlessCJ1W-AD04U(SL)error detection4Analog input0 to 5 V,0 to 10 V,–10 to 10 V,1 to5 V,4 to 20 mA1/8,000V: 0.2% I: 0.4%250 μs/point 31 mmOffset/gain adjustment, peak hold, moving average, alarmsM3 CJ1W-AD041-V1ScrewlessCJ1W-AD041-V1(SL)4High-speed analog input1 to5 V,0 to 10 V,–5 to 5 V,–10 to 10 V,4 to 20 mA1/40,000V: 0.2% I: 0.4%35 μs/4 points 31 mmDirect conversion (CJ2H special instruc- tion)M3 CJ1W-AD0428Analog input1 to 5 V,0 to5 V,0 to 10 V,–10 to 10 V,4 to 20 mA1/8,000V: 0.2% I: 0.4%250 μs/point 31 mmOffset/gain adjustment, peak hold, moving average, alarmsM3 CJ1W-AD081-V1ScrewlessCJ1W-AD081-V1(SL)2Analog output 0 to 5 V,0 to 10 V,–10 to 10 V,1 to5 V,4 to 20 mA4Analog output 1 to 5 V,0 to5 V,0 to 10 V,–10 to 10 V,4 to 20 mA1/4,000V: 0.3% I: 0.5%1/4,000V: 0.3% I: 0.5%1 ms/point31 mmOffset/gain adjustment, output holdM3CJ1W-DA021ScrewlessCJ1W-DA021(SL)1 ms/point31 mmOffset/gain adjustment, output holdM3CJ1W-DA041ScrewlessCJ1W-DA041(SL)4High-speed analog output1 to5 V,0 to 10 V,–10 to 10V1/40,0000.3%35 μs/4 points 31 mmDirect conversion (CJ2H special instruc- tion)M3 CJ1W-DA042V8Voltage output 0 to 5 V,0 to 10 V,–10 to 10 V,1 to5V1/8,0000.3%250 μs/point 31 mmOffset/gain adjustment, output holdM3CJ1W-DA08V ScrewlessCJ1W-DA08V (SL)8Current output 4 to 20 mA 1/8,0000.3%250 μs/point 31 mmOffset/gain adjustment, output holdM3CJ1W-DA08C ScrewlessCJ1W-DA08C(SL)4 + 2 Analog in + output 1 to 5 V,1/8,000in: 0.2%1 ms/point31 mmOffset/gain adjustment, scaling, peak hold, M3 CJ1W-MAD420 to5 V,0 to 10 V,–10 to 10 V,4 to 20 mAout: 0.3%moving average, alarms, output holdScrewlessCJ1W-MAD42(SL)4Universal analog inputDC voltage, DC current, Thermocouple, Pt100/Pt1000, potentiometer1/256,0000.05%60 ms/4 points 31 mmAll inputs individually isolated, configu- rable alarms, maintenance functions, user-defined scaling, zero/span adjust- mentM3 CJ1W-PH41U2Process input 4 to 20 mA0 to 20 mA0 to 10 V,–10 to 10 V,0 to5 V,–5 to 5 V,1 to5 V,0 to 1.25 V,1.25 to 1.25 V1/64,0000.05%5 ms/point31 mmConfigurable alarms, maintenance functions, user-defined scaling, zero/span adjustment, square root, totaliserM3 CJ1W-PDC1532CJ-Series analogI/O and controlunitsModular PLCPointsType RangesResolution Accuracy*1Conversion timeWidth RemarksConnection typeOrder code2ThermocoupleB, E, J, K, L, N, R, S, T,1/64,0000.05%5 ms/point31 mmConfigurable alarms, maintenancefunc-M3 CJ1W-PTS15input4ThermocoupleInputU, WRe5-26, PLII,–100 to 100 mVB, J, K, L, R, S, Ttions0.1°C 0.3%62.5 ms/point 31 mm4 configurable alarm outputsM3CJ1W-PTS514Resistance ther- mometer inputPt100, JPt1000.1°C 0.3%62.5 ms/point 31 mm4 configurable alarm outputsM3CJ1W-PTS526Thermocouple input6Resistance ther- mometer inputK-type(–200 to1,300°C) J-Type(–100 to 850°C)Pt100(–200 to 650°C) Pt1000(–200 to 650°C)0.1°C 0.5%40 ms/point31 mmBasic I/O unit, setup by DIP switches, adjustable filtering 10/50/60 Hz0.1°C 0.5%40 ms/point31 mmBasic I/O unit, setup by DIP switches, adjustable filtering 10/50/60 HzM3 CJ1W-TS561ScrewlessCJ1W-TS561 (SL)M3 CJ1W-TS562ScrewlessCJ1W-TS562 (SL)4Temperature con-B, J, K, L,0.1°C 0.3%500 ms total31 mm4 control outputs: PNP openM3 CJ1W-TC002trol loops, Ther- mocoupleR, S, Tcollector, 100 mA max.2Temperature con-B, J, K, L,0.1°C 0.3%500 ms total31 mm2 control outputs: PNP openM3 CJ1W-TC004trol loops, Ther- mocoupleR, S, Tcollector, 100 mA max., 2 current trans- former inputs for heater burnout detec-tion.4Temperature con-Pt100, JPt1000.1°C 0.3%500 ms total31 mm4 control outputs: PNP openM3 CJ1W-TC102trol loops, RTDcollector, 100 mA max.2Temperature con-Pt100, JPt1000.1°C 0.3%500 ms total31 mm2 control outputs: PNP openM3 CJ1W-TC104trol loops, RTD1Load Cell Interface 10 VDC or 2.5 VDC,collector, 100 mA max., 2 current trans- former inputs for heater burnout detec-tion.24 bit, 0.1μV/ Linearity error:0.33 ms 31 mmSelf-contained unit designed for fastM3 CJ1W-F130unitmax. four 350 load count cells.<0.02%FSweight and force measurement.Low-pass filter adjustable 3 Hz - 1 kHz. Made by Unipulse Co.1Weighing unit10 VDC, max. four24 bit, 0.3μV/ Linearity error:2 ms 31 mmSelf-contained unit designed for feedM3 CJ1W-F159350 load cellscount<0.01%FSweighing, discharge weighing, hopper scales, packing scales, bag filling, etc. Made by Unipulse Co.*1Accuracy for Voltage and Current Inputs/Outputs as percentage of full scale and typical value at 25°C ambient temperature (Consult the operation manual for details) Accuracy for Temperature Inputs/Outputs as percentage of process value and typical value at 25°C ambient temperature (Consult the operation manual for details)Note:All Analog I/O units are designated as Special I/O units, exceptTS561/TS562, which are Basic I/O units (cannot be used with CP1H).AccessoriesDescription Connection typeOrder codeReplacement 18-point screwless terminal blocks for I/O units, pack of 5 pcs. ScrewlessCJ-WM01-18P-5Replacement 18-point screw terminal blocks for I/O units, pack of 5 pcs.M3 CJ-OD507-18P-533

製品資料

データシート

技術仕様と性能データ

ユーザーマニュアル

設置・操作ガイド

Top