Temp. controller, PROplus, ,1/4 DIN, (48 x 96)mm,Pos. Prop. Control,2 x Aux OUT,2 Event I/Ps,option unit,100-240V AC
主な機能
産業グレードの品質
RoHS準拠
CE認証取得
1年保証
技術的詳細
E5_N-H/E5_N-HTAdvanced and Multi-Loop controllersUniversal compact digital process controllersThe E5_N-H series of process controllers take the proven concept of the general pur- pose E5_N series to a process level. Main featuresof the E5_N-H series are universalinputs, process outputs and options such as transfer output, remote setpoint and set- value programmer.• Control mode: ON/OFF or 2-PID, Valve control on EN-H/AN-H• Control output: relay, voltage (pulse), SSR, linear current and voltage• Power supply: 100/240 VAC or 24 VDC/VAC•Easy PC connection for parameter cloning, setting and tuning• Clear and intuitive set-up and operationOrdering informationTypeInputOutputFixed option AlarmsOrder code48x48 mm model (includes supply voltage indication)On-panelUniversalRelay output– 3 software alarmsE5CN-HR2M-500 AC100-240E5CN-HR2MD-500 AC/DC24TC/Pt/mVmA/VVoltage (pulse)2 SUB outputsE5CN-HQ2M-500 AC100-240E5CN-HQ2MD-500 AC/DC24Current outputE5CN-HC2M-500AC100-240E5CN-HC2MD-500AC/DC24Linear voltage outputE5CN-HV2M-500 AC100-240E5CN-HV2MD-500 AC/DC24Relay outputSV programmerE5CN-HTR2M-500 AC100-240E5CN-HTR2MD-500 AC/DC24Voltage (pulse)(8 programs of32 segments)E5CN-HTQ2M-500 AC100-240E5CN-HTQ2MD-500 AC/DC24Current outputE5CN-HTC2M-500 AC100-240E5CN-HTC2MD-500 AC/DC24Linear voltage outputE5CN-HTV2M-500 AC100-240 E5CN-HTV2MD-500 AC/DC24Note:- Output and Alarm Relays: 3 A/250 VAC, electrical life: 100,000 operations- Output voltage (pulse): 12 V, 21 mA (ie. to drive solid state relays)- Linear current: 0(4) to 20 mA- Linear voltage output: 0 to 10 VAccessoriesE5CN-H option boards(One slot available in each instrument)OptionOrder codeEvent inputsE53-CNBN2Event inputsControl output 2Voltage (for driving SSR)Event inputs Heater burnout/SSR failure/Heater overcurrent detectionE53-CNQBN2E53-CNHBN2Event inputsTransfer output E53-CNBFN2Communications RS-232C Control output 2E53-CN01N2Communications RS-232CVoltage (for driving SSR)E53-CNQ01N2Communications RS-232C Heater burnout/SSR failure/HeaterE53-CNH01N2Communications RS-485Communications RS-485Control output 2Voltage (for driving SSR)overcurrent detectionE53-CN03N2E53-CNQO3N2Communications RS-485Heater burnout/SSR failure/Heater overcurrent detectionCommunications RS-4853-phase heater burnout/SSR failure/ Heater overcurrent detectionE53-CNH03N2E53-CNHH03N2Control output 2Voltage (for driving SSR)Transfer output E53-CNQFN2Control output 2Voltage (for driving SSR)Control output 2Voltage (for driving SSR)Heater burnout/SSR failure/Heater overcurrent detection3-phase heater burnout/SSR failure/ Heater overcurrent detectionE53-CNQHN2E53-CNQHHN2529E5_N-H/E5_N-HTAdvanced and Multi-Loop controllersControl method Auxiliary output Control output 1/2Heater burnoutTransfer outputOrder code (includes supply voltage indication)96 × 96 mm model48 × 96 mm modelBasic2 alarm relaysnone fitted, 2 slots 1-phase E5AN-HAA2HBM-500 AC100-240E5EN-HAA2HBM-500 AC100-240 none fitted, 2 slots E5AN-HAA2HBMD-500 AC/DC24E5EN-HAA2HBMD-500 AC/DC242 SSR output fitted E5AN-HSS2HBM-500 AC100-240E5EN-HSS2HBM-500AC100-2402 SSR output fitted E5AN-HSS2HBMD-500AC/DC24 E5EN-HSS2HBMD-500AC/DC24 none fitted, 2 slots 3-phase 4 to 20 mA outputE5AN-HAA2HHBFM-500AC100-240 E5EN-HAA2HHBFM-500AC100-240 none fitted, 2 slots E5AN-HAA2HHBFMD-500AC/DC24E5EN-HAA2HHBFMD-500AC/DC242 SSR output fitted E5AN-HSS2HHBFM-500 AC100-240E5EN-HSS2HHBFM-500 AC100-2402 SSR output fitted E5AN-HSS2HHBFMD-500AC/DC24E5EN-HSS2HHBFMD-500AC/DC243 alarm relaysnone fitted, 2 slots E5AN-HAA3BFM-500 AC100-240 E5EN-HAA3BFM-500 AC100-240 none fitted, 2 slots E5AN-HAA3BFMD-500 AC/DC24 E5EN-HAA3BFMD-500 AC/DC242 SSR output fitted E5AN-HSS3BFM-500 AC100-240E5EN-HSS3BFM-500 AC100-2402 SSR output fitted E5AN-HSS3BFMD-500AC/DC24E5EN-HSS3BFMD-500AC/DC24Valve controller2 alarm relays2 relay output fittedE5AN-HPRR2BM-500AC100-240E5EN-HPRR2BM-500 AC100-240E5AN-HPRR2BMD-500AC/DC24 E5EN-HPRR2BMD-500 AC/DC244 to 20 mA outputE5AN-HPRR2BFM-500 AC100-240 E5EN-HPRR2BFM-500 AC100-240E5AN-HPRR2BFMD-500 AC/DC24 E5EN-HPRR2BFMD-500AC/DC24SV programmer(8 programs of32 segments2 alarm relaysnone fitted, 2 slots 1-phase E5AN-HTAA2HBM-500E5EN-HTAA2HBM-500AC100-240E5AN-HTAA2HBMD-500 E5EN-HTAA2HBMD-500AC/DC243-phase 4 to 20 mA outputE5AN-HTAA2HHBFM-500 E5EN-HTAA2HHBFM-500E5AN-HTAA2HHBFMD-500E5EN-HTAA2HHBFMD-5003 alarm relaysE5AN-HTAA3BFM-500 E5EN-HTAA3BFM-500E5AN-HTAA3BFMD-500E5EN-HTAA3BFMD-500SV programmer and 2 alarm relays2 relay output fittedE5AN-HTPRR2BM-500 E5EN-HTPRR2BM-500valve controllerNote:- All E5EN-H/AN-H have 2 event inputs- All E5EN-H/AN-H have Remote Setpoint 4 to 20 mA inputE5AN-HTPRR2BMD-500E5EN-HTPRR2BMD-5004 to 20 mA outputE5AN-HTPRR2BFM-500 E5EN-HTPRR2BFM-500E5AN-HTPRR2BFMD-500E5EN-HTPRR2BFMD-500Specifications E5CN-H/EN-H/AN-H E5AN-H/EN-H output option boardsE5CN-H(T) E5EN-H(T) E5AN-H(T) Supply voltage 100 to 240VAC 50/60 Hz or 24 VAC, 50/60Hz 24 VDC Sensor input Thermocouple: K, J, T, E, L, U, N, R, S, B, W or PL IIPlatinum resistance thermometer: Pt100 or JPt100Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V or 0 to 10 VControl mode ON/OFF, 2-PID and valve (PRR)Accuracy Thermocouple: (± 0.1% of indicated value or ±1°C, whichever is greater) ± digit max.Platinum resistance thermometer: (± 0.1% of indicated value or± 0.5°C, whichever is greater) ± 1 digit max. Analog input: ± 0.1% FS ± 1 digit max.Auto-tuning yes, 40% and 100%MV output limit selection. When usingHeat/Cool: automatic cool gain adjustmentSelf-tuning yesRS-232C/RS-422/RS-485 optional, CompowayF or Modbus selectableEvent input Optional (Standard 2 event input in EN-H/AN-H)(2 slots available in E5_N-HAA__-500 models:SS modelshave2 fixed SSR output modules)OptionOrder code RelayE53-RN Voltage(pulse) PNP 12 VDCE53-QN Voltage(pulse) NPN 24 VDCE53-Q3Voltage(pulse) PNP 24 VDCE53-Q4Linear 4 to 20 mAE53-C3N Linear 0 to 20 mAE53-C3DN Linear 0 to 10 V E53-V34N Linear 0 to 5 V E53-V35NE5AN-H/EN-H option boards(one slot available in each instrument)OptionOrder codeRS-232C communications (CompoWay/F/Modbus) E53-EN01RS-422 communications (CompoWay/F/Modbus)E53-EN02QLP port(USB connection PC)yesRS-485 communications (CompoWay/F/Modbus)E53-EN03Event inputE53-AKBAmbient temperature –10 to 55°CIP Rating front panel IP66Sampling period 60 msSizes*1 in mm (W × H × D)48×48×76.548×96×77.296×96×77.2*1With mounted terminal coverE5AN-H/EN-H series optional toolsOptionOrder codeUSB PC based configuration cableE58-CIFQ1PC based configuration and tuning software CX-ThermoEST2-2C-MV4530