| パラメータ | 価値 |
|---|---|
| Ue | |
| DC | Resistive load (DC-12) |
| つまり | AC |
| B10D | 2,000,000(ISO 13849-1 Annex C Table C.1) |
| アイテム | Specifications |
| ケーブル | UL style 2464, No.22 AWG 12-core |
| 重さ | Approx. 700 g |
| 製品 | Safety door switch with key |
| 材料 | Enclosure : PA66 |
| 保護 | IP 65 (IEC 60529) |
| 部品番号 | SG-B2-K2BD-L5 |
| ケーブル長 | 5m16.404 ft |
| 製品名 | Safety door switch with key SG-B2 |
| 製品番号 | SG-B2-K2BD-L5 |
| インターロック力 | 1,400 N min. (GS-ET-19)(Note)(500 N min. : SG-K24 actuator)(Note): The actuator locking strength is rated at 1,400 N of static load. Do not apply a load higher than the rated value. When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. |
| 耐衝撃性 | Malfunction : 100 m/s2, Destruction : 1,000 m/s2 |
| 接触抵抗 | 700 mΩ max. (initial value, 5 m16.404 ftcable) |
| 連絡先 | |
| 動作周波数 | 900 operations/hour |
| 適用可能な基準 | EN 1088, IEC 60947-5-1, EN 60947-5-1,GS-ET-19, UL 508, CSA C22.2 No.14 |
| 直接開放力 | 80 N min. |
| キー取り外し位置 | B(removable in UNLOCK position) |
| 耐振動性 | Malfunction : 10 to 55 Hz, half amplitude 0.35 mm0.014 inDestruction : 30 Hz, half amplitude 1.5 mm0.059 in |
| 適用される指令 | Machinery directive (2006/42/EC)Low voltage directive (2006/95/EC) |
| 直接開閉移動 | 11 mm0.433 inmin. (actuator : SG-K21)12 mm0.472 inmin. (for other actuators) |
| 電気的耐久性 | 100,000 operations min. (AC-12, 250 V 1 A)1,000,000 operations min. (AC/DC 24 V 100 mA)(900 operations/hour) |
| 機械的耐久性 | 1,000,000 operations min. (GS-ET-19)Rear unlocking button : 3,000 operations min. (Type SG-B2-□-L5) |
| 熱電流(Ith) | ・2.5 A・Ambient temperature :-25 to +60 ℃-13 to +140 ℉: 2.5 A max.+60 to +65 ℃+140 to +149 ℉: 1.5 A max.+65 to +70 ℃+149 to +158 ℉: 1.0 A max. |
| 誘導負荷(AC-15) | - |
| 誘導負荷(DC-13) | 2.3A |
| アクチュエータの動作速度 | 0.05 to 1.0 m/sec. |
| キー:直接開放力 | 0.6 N・m min. |
| キー:キー引張強度 | 1.0 N・m min. |
| キー:直接開度 | 60°min. |
| キー:機械的耐久性 | 100,000 operations min. |
| 定格絶縁電圧(Ui) | 250 V(Note): Ratings approved by UL, c-UL : 125 V |
| キー:キー操作耐久性 | 10,000 operations min. |
| キー:動作仕様 | 2 positions |
| 動作条件:高度 | 2,000 m6,561.68 ftmax. |
| 感電保護クラス | Class II (IEC 61140)(Note), 回(double-insulated)(Note): Basic insulation of 2.5 kV impulse withstand voltage is ensured between different contact circuits.When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. |
| 短絡保護装置 | Use 250 V / 10 A fast acting type fuse |
| インパルス耐電圧(Uimp) | 2.5 kV |
| 条件付き短絡電流 | 50 A (250 V) |
| 動作条件:周囲湿度 | 45 to 85 % RH |
| 動作条件:汚染度 | 3 (Inside 2) |
| 適用規格:使用規格 | IEC 60204-1, EN 60204-1 |
| 動作条件:周囲温度 | -25 to +70 ℃-13 to +158 ℉(No dew condensation or icing allowed)Storage : -40 to +80 ℃-40 to +176 ℉ |
| 定格動作電圧(Ue)/定格動作電流(Ie) | Ue30V125V250VIeACResistive load (AC-12)-2.5A1.5AInductive load (AC-15)-1.5A0.75ADCResistive load (DC-12)2.5A1.1A0.55AInductive load (DC-13)2.3A0.55A0.27A |
技術仕様と性能データ