サービス時間: 月曜日~金曜日 9:00-18:00
USFC11 - USFC11 SFC11 SF-C11 PANASONIC Control unit for SF4B, connector type
在庫あり 注目商品

USFC11

USFC11 SFC11 SF-C11 PANASONIC Control unit for SF4B, connector type

$0.00米ドル
4500 在庫あり
主な仕様
アイテム:Specifications
重さ:Net weight: 320 g approx.
詳細:Connector connection type control unit
製品:Exclusive Control Unit for Safety Light Curtain
サプライヤー情報
PANASONIC
PANASONIC
製品: 4316
通常、2〜3営業日以内に出荷します
品質保証済み
高速配送
テクニカルサポート

技術仕様

パラメータ価値
アイテムSpecifications
重さNet weight: 320 g approx.
詳細Connector connection type control unit
製品Exclusive Control Unit for Safety Light Curtain
ヒューズ定格Built-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down
部品番号SF-C11
製品名Exclusive Control Unit for Safety Light Curtain SF-C10
電源電圧24 V DC ±10 % Ripple P-P 10 % or less / 100 mA or less (without safety light curtain)
応答時間10 ms or less
安全出力NO contact × 3 (13-14, 23-24, 33-34)
製品番号SF-C11
周囲の湿度30 to 85 % RH, Storage: 30 to 95 % RH
汚染度2
補助出力Safety relay contact (NC contact) × 1 (41-42) (Related to enabling path)
エンクロージャ材質ABS
周囲温度-10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158℉
接続端子Detachable spring-cage terminal
消費電流100 mA or less (without light curtain)
過電圧カテゴリーII
耐振動性Resistance / malfunction 10 to 55 Hz frequency, 0.35 mm0.014 inamplitudein X, Y, and Z directions for twenty times each
後縁関数Incorporated
インジケーター:障害 (FAULT)Yellow LED (blinks when fault occurs)
適用規格:日本JIS B 9704-1 (Type 4), JIS B 9705-1(Category 4),
極性選択機能Incorporated (Sliding switch allows selection of plus/minus ground)Minus ground: Correspond to PNP output safety light curtainPlus ground: Correspond to NPN output safety light curtain(Note:Please switch the sliding switch to the PNP side for minus ground and to the NPN side for plus ground.)
インジケーター:電源(Ui)Green LED (lights up when the power is ON)
インジケーター:安全出力[OUT]Green LED (lights up when safety output is closed)(Note:The operation indicator is marked as "Enabling" on the unit forSF-C12.)
CEマーキング指令への準拠Machinery Directive, Low Voltage (SF-C11/C13 only) Directive, EMC Directive, RoHS Directive
外部リレーモニター機能Incorporated
適用規格:欧州(EU)EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1 (Category 4, PLe), ISO 13849-1 (Category 4, PLe)
安全出力:接触抵抗100 mOhm or less (initial value)
接続可能なセーフティライトカーテンSF4D / SF4B / SF4B-G / SF2Bseries
インジケーター:インターロック (INTER_LOCK)Yellow LED (lights up when safety output is opened)
安全出力:電気寿命100,000 times or more (open/close frequency of 20 times/min, 230 V AC, 3 A, using resistance load)(Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.)
安全出力:機械寿命10,000,000 times or more (open/close frequency of 180 times/min)(Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.)
適用規格:北米ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2) (Note:SF-C11andSF-C13comply with UL 1998 (Class 2).)
安全出力:アプリケーションカテゴリAC-15, DC-13 (IEC 60947-5-1)
半導体補助出力(AUX)<Minus ground (Setting for PNP)>PNP open-collector transistor・Max. source current: 60 mA・Applied voltage: sameas supply voltage(between the semiconductor auxiliary output and +V)・Residual voltage: 2.3 V or less (at source current 60 mA)Leakage current: 2 mA or less<Plus ground (Setting for NPN)>NPN open-collector transistor・Max. sink current: 60 mA・Applied voltage: same as supply voltage(between the semiconductorauxiliary output and 0 V)・Residual voltage: 1.5 V or less(at sink current 60 mA)Leakage current: 2 mA or less
ピックアップ遅延(自動リセット/手動リセット)80 ms or less / 90 ms or less
安全出力:接点材質/接点AgSnO, self cleaning, positively driven
適用規格:国際規格IEC 61496-1 (Type 4)
安全出力:接触保護ヒューズ定格6 A (slow blow)
環境耐性:保護等級Enclosure: IP40Terminal: IP20
補助出力:接触保護ヒューズ定格2 A (slow blow)
補助出力:定格動作電圧/電流24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC)
半導体補助出力(AUX):出力動作Related to auxiliary output of safety light curtain
安全出力:定格動作電圧(Ue)/定格動作電流(le)6 A / 30 V DC, 6 A / 230 V AC, resistive load (For inductive load, during contact protection) Min. applicable load: 10 mA (at 24 V DC)(Note:If severalSF-C11orSF-C13units are being used in a line together, leavea space of 5 mm0.197 inor more between each unit. If the units are touching each other, reduce the rated operating current for safety output in accordance with the ambient operating temperature as shown in the graphs below.)

製品説明

DIN rail control unit for SF2B/SF4B, applicable to 8-wire cables with connector, control up to category 4
主な機能
  • 産業グレードの品質
  • RoHS準拠
  • CE認証取得
  • 1年保証

製品資料

データシート

技術仕様と性能データ

ユーザーマニュアル

設置・操作ガイド

Top