| パラメータ | 価値 |
|---|---|
| アイテム | Specifications |
| 重さ | Net weight: 320 g approx. |
| 詳細 | Connector connection type control unit |
| 製品 | Exclusive Control Unit for Safety Light Curtain |
| ヒューズ定格 | Built-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down |
| 部品番号 | SF-C11 |
| 製品名 | Exclusive Control Unit for Safety Light Curtain SF-C10 |
| 電源電圧 | 24 V DC ±10 % Ripple P-P 10 % or less / 100 mA or less (without safety light curtain) |
| 応答時間 | 10 ms or less |
| 安全出力 | NO contact × 3 (13-14, 23-24, 33-34) |
| 製品番号 | SF-C11 |
| 周囲の湿度 | 30 to 85 % RH, Storage: 30 to 95 % RH |
| 汚染度 | 2 |
| 補助出力 | Safety relay contact (NC contact) × 1 (41-42) (Related to enabling path) |
| エンクロージャ材質 | ABS |
| 周囲温度 | -10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158℉ |
| 接続端子 | Detachable spring-cage terminal |
| 消費電流 | 100 mA or less (without light curtain) |
| 過電圧カテゴリー | II |
| 耐振動性 | Resistance / malfunction 10 to 55 Hz frequency, 0.35 mm0.014 inamplitudein X, Y, and Z directions for twenty times each |
| 後縁関数 | Incorporated |
| インジケーター:障害 (FAULT) | Yellow LED (blinks when fault occurs) |
| 適用規格:日本 | JIS B 9704-1 (Type 4), JIS B 9705-1(Category 4), |
| 極性選択機能 | Incorporated (Sliding switch allows selection of plus/minus ground)Minus ground: Correspond to PNP output safety light curtainPlus ground: Correspond to NPN output safety light curtain(Note:Please switch the sliding switch to the PNP side for minus ground and to the NPN side for plus ground.) |
| インジケーター:電源(Ui) | Green LED (lights up when the power is ON) |
| インジケーター:安全出力[OUT] | Green LED (lights up when safety output is closed)(Note:The operation indicator is marked as "Enabling" on the unit forSF-C12.) |
| CEマーキング指令への準拠 | Machinery Directive, Low Voltage (SF-C11/C13 only) Directive, EMC Directive, RoHS Directive |
| 外部リレーモニター機能 | Incorporated |
| 適用規格:欧州(EU) | EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1 (Category 4, PLe), ISO 13849-1 (Category 4, PLe) |
| 安全出力:接触抵抗 | 100 mOhm or less (initial value) |
| 接続可能なセーフティライトカーテン | SF4D / SF4B / SF4B-G / SF2Bseries |
| インジケーター:インターロック (INTER_LOCK) | Yellow LED (lights up when safety output is opened) |
| 安全出力:電気寿命 | 100,000 times or more (open/close frequency of 20 times/min, 230 V AC, 3 A, using resistance load)(Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.) |
| 安全出力:機械寿命 | 10,000,000 times or more (open/close frequency of 180 times/min)(Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.) |
| 適用規格:北米 | ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2) (Note:SF-C11andSF-C13comply with UL 1998 (Class 2).) |
| 安全出力:アプリケーションカテゴリ | AC-15, DC-13 (IEC 60947-5-1) |
| 半導体補助出力(AUX) | <Minus ground (Setting for PNP)>PNP open-collector transistor・Max. source current: 60 mA・Applied voltage: sameas supply voltage(between the semiconductor auxiliary output and +V)・Residual voltage: 2.3 V or less (at source current 60 mA)Leakage current: 2 mA or less<Plus ground (Setting for NPN)>NPN open-collector transistor・Max. sink current: 60 mA・Applied voltage: same as supply voltage(between the semiconductorauxiliary output and 0 V)・Residual voltage: 1.5 V or less(at sink current 60 mA)Leakage current: 2 mA or less |
| ピックアップ遅延(自動リセット/手動リセット) | 80 ms or less / 90 ms or less |
| 安全出力:接点材質/接点 | AgSnO, self cleaning, positively driven |
| 適用規格:国際規格 | IEC 61496-1 (Type 4) |
| 安全出力:接触保護ヒューズ定格 | 6 A (slow blow) |
| 環境耐性:保護等級 | Enclosure: IP40Terminal: IP20 |
| 補助出力:接触保護ヒューズ定格 | 2 A (slow blow) |
| 補助出力:定格動作電圧/電流 | 24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC) |
| 半導体補助出力(AUX):出力動作 | Related to auxiliary output of safety light curtain |
| 安全出力:定格動作電圧(Ue)/定格動作電流(le) | 6 A / 30 V DC, 6 A / 230 V AC, resistive load (For inductive load, during contact protection) Min. applicable load: 10 mA (at 24 V DC)(Note:If severalSF-C11orSF-C13units are being used in a line together, leavea space of 5 mm0.197 inor more between each unit. If the units are touching each other, reduce the rated operating current for safety output in accordance with the ambient operating temperature as shown in the graphs below.) |
技術仕様と性能データ
設置・操作ガイド