Three-phase power analyzer, built-in programming keypad, basic version, DIN rail
主な機能
  • 産業グレードの品質
  • RoHS準拠
  • CE認証取得
  • 1年保証

技術的詳細

Energy ManagementPower AnalyzerType WM14-DIN “Basic Version”• Class 1 (active energy)• Class 2 (reactive energy)• Accuracy ±0.5 F.S. (current/voltage)• Power analyzer• Display of instantaneous variables: 3x3 digit• Display of energies: 8+1 digit• System variables and phase measurements: W, Wdmd, var, VA, VAdmd, PF, V, A, An, Admd, Hz• Amax, Admd max, Wdmdmaxindication• Energy measurements: kWh and kvarh• Hour counter (5+2 DGT)• TRMS meas. of distorted sine waves (voltages/currents)• Power supply: 24V, 48V, 115V, 230V, 50-60Hz 18 to 60VDC• Optional dual pulse output• Alarms (visual only) VLN, An• Optional galvanically insulated measuring inputsProduct Description• Protection degree (front): IP40• Front dimensions: 107.8x90mm• Optional RS422/485 serial portHow to orderWM14-DIN AV5 3 D PGX3-phase power analyzer with built-in programming key- pad. Particularly recom- mended for displaying the main electrical variables. Housing for DIN-rail mount-ing, (front) protection degree IP40, and optional RS485 serial port or dual pulse out- put. Parameters pro- grammable by means of CptBSoft.Model Range code SystemPower supplyOptionHow toorderCptBSoftType SelectionCptBSoft (compatible only with S or SG options): software to program the working parameters of the power analyzer and to read the energy and the instantaneous variables.Range codesAV5: 380/660VL-L/5(6)AAC VL-N: 185 V to 460 V VL-L: 320 V to 800 VAV6: 120/208VL-L/5(6)AAC VL-N: 45 V to 145 VVL-L: 78 V to 250 V Phase current: 0.03A to 6A Neutral current: 0.09 to 6AInputspecificationsSystem3 :1-2-3-phase, balanced/unbalanced load,with or without neutralPower supplyA: 24VAC-15+10%, 50-60HzB: 48VAC-15+10%, 50-60HzC: 115VAC-15+10%, 50-60HzD: 230VAC-15+10%, 50-60Hz3:18 to 60VDC (not available in case of SG or PG options)OptionsX: NoneS: RS485 portSG:RS485+galvanic insu- lated measurig inputsPG:Dual pulse output+ galvanically insulated measuring inputs.Rated inputsCurrent “X-S options”3 (non insulated each other) Current “SG-PG options”3 (insulated each other) Voltage4Accuracy (display, RS485)with CT=1 and VT=1 AV5: (@25°C ±5°C, R.H. ≤60%)1150W-VA-var, FS:230VLN,400VLL AV6: 285W-VA-var, FS:57VLN, 100VLLCurrent 0.25 to 6A: ±(0.5% FS +1DGT)0.03Ato0.25A:±(0.5%FS+7DGT) Neutral current0.25 to 6A: ±(1.5% FS +1DGT)0.09Ato0.25A:±(0.5%FS+7DGT)Phase-phase voltage ±(1.5% FS +1 DGT) Phase-neutral voltage ±(0.5% FS + 1 DGT)Active and Apparent power,0.25 to 6A: ±(1% FS +1DGT)0.03A to 0.25A: ±(1% FS+5DGT) Reactive power 0.25 to 6A: ±(2% FS +1DGT)0.03A to 0.25A: ±(2% FS+5DGT)Active energy “X-S option” Class 2 (start up “I”: 30mA) Reactive energy “X-S option”Class 3 (start up “I”: 30mA) Active energy “SG-PG opt.” Class 1 (start up “I”: 30mA) Reactive energy “SG-PG opt.” Class 2 (start up “I”: 30mA) Frequency±0.1Hz (48 to 62Hz)Additional errorsHumidity≤0.3% FS, 60% to 90% RHTemperature drift≤ 200ppm/°CSampling rate1400 samples/s @ 50Hz1700 samples/s @ 60HzDisplay refresh time700msDisplayTypeLED, 9mmRead-out for instant. var.3x3 DGTRead-out for energies 3+3+3 DGT (Max indication:999 999 99.9)Read-out for hour counter 1+3+3 DGT (Max. indication:9 999 9.99)Specifications are subject to change without noticeWM14 DIN B DS ENG210508 1

製品資料

データシート

技術仕様と性能データ

ユーザーマニュアル

設置・操作ガイド

Top