HC-HS 2-D7-EBUS - HC-HS 2-D7-EBUS 1586264 PHOENIX CONTACT Contact insert
在庫あり 注目商品

HC-HS 2-D7-EBUS

HC-HS 2-D7-EBUS 1586264 PHOENIX CONTACT Contact insert

$35.46米ドル
326 在庫あり
主な仕様
:Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
タイプ:D7
テスト:DIN VDE 0627/86
幅:21 mm
サプライヤー情報
製品: 0
通常、2〜3営業日以内に出荷します
品質保証済み
高速配送
テクニカルサポート

技術仕様

パラメータ価値
Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
タイプD7
テストDIN VDE 0627/86
21 mm
身長34.8 mm
長さ21 mm
シリーズHC-HS
一般的なfor HC-D7 housing, axial connection 2.0 mm, Allen key
応用Power
製品タイプContact insert with a fixed no. of positions
組み立てノートTo ensure correct use, installation in housing with IP54 protection or better is required
定格電流40 A
記事の改訂04
接触直径4 mm
接触材料Copper alloy
六角ソケットSW2,0
連絡先番号1 - 2
締め付けトルク0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing)
接続プロファイル2+PE
汚染度3
寸法図
ポジション数2
定格サージ電圧6 kV
過電圧カテゴリーIII
接続技術Axial screw connection
接触材料の種類turned
電源接点数2
定格電圧(III/3)400 V
導体断面積4 mm² ... 10 mm² (The cross section specification refers to the geometric cross section of the cable used)
接触キャリア材料PC
接触面材質Ag
挿入/離脱サイクル≥ 500
接続断面積AWG10 ... 8
周囲温度(動作)-40 °C ... 125 °C (including heating up of contacts)
標準に準拠した接続IEC / EN
構造および試験規制DIN VDE 0627/86
UL 94準拠の難燃性評価V0
個々の電線の被覆剥き長さ8 mm +1 mm

製品説明

Contact insert, number of poles: 2+PE, size: D7, power contacts: 2, Female, Axial screw connection, 400 V, 40 A, 4 mm² ... 10 mm², Application: Power
主な機能
  • 産業グレードの品質
  • RoHS準拠
  • CE認証取得
  • 1年保証

製品資料

データシート

技術仕様と性能データ

ユーザーマニュアル

設置・操作ガイド